FLT -100℃~+80℃
Reverse ltricat cooling system
- Temperture accuracy±0.1℃
- Cooling Power0.6~3kW
- Heating Power2~3.5kW
- Flow Control12~45L/min
- Heat Transfer OilFluorinated fluid
Configuration Details
Model | FLT-803W | FLT-805W | FLT-806W | FLT-808W | FLT-810W |
Temp Range | -80℃~+80℃ | ||||
Temperature Control Accuracy | ±0.1℃ | ||||
Flow Control | 7~25L/min | 12~45L/min | |||
The flow control is adjusted by a frequency converter, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 6bar | |||||
Cooling Power @-70℃ | 0.6KW | 1KW | 1.5KW | 2KW | 3KW |
Heating Power | 2KW | 2KW | 2KW | 3.5KW | 3.5KW |
Internal circulation fluid volume | 4L | 5L | 6L | 8L | 10L |
Expansion tank volume | 10L | 10L | 15L | 15L | 20L |
Heat transfer medium | Fluorinated liquid | ||||
In and out interface | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 |
Cooling water interface | ZG3/4 | ZG3/4 | ZG3/4 | G1 | G1 |
Cooling water @20℃ | 1.8m3/h | 2.5m3/h | 3m3/h | 5m3/h | 6m3/h |
Source | 380V 50HZ | ||||
Breaker | 25A | 25A | 32A | 40A | 50A |
Model | FLT-1002W | FLT-1004W |
Temp Range | -100℃~+80℃ | -100℃~+80℃ |
Temperature control accuracy | ±0.1℃ | ±0.1℃ |
Flow Control | 7~25L/min | 12~45L/min |
The flow control is adjusted by a frequency converter, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 6bar | ||
Cooling Power @-90℃ | 1.5KW | 3KW |
Heating Power | 3.5KW | 5.5KW |
Internal circulation fluid volume | 5L | 8L |
Expansion tank volume | 10L | 15L |
Heat transfer medium | Fluorinated liquid | |
Heat transfer medium interface | G3/4 | G3/4 |
Cooling water interface | G3/4 | G1 |
Cooling water @20℃ | 50L/min 2bar~7bar | 100L/min 2bar~7bar |
Source | 380V 50HZ | 380V 50HZ |
Breaker | 32A | 63A |
Size | 700*800*1850 | 800*1200*1850 |
Product Description
Product Applications
Recommended ProductsUsed for Water Test
- More
LTS -80℃~80℃
LTS -80℃~80℃ Fluorinated liquid temperature control system AFor chip testing · Temperature Control Accuracy ±0.1℃ at -80℃~-50℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser A…
- More
LTS -60℃~80℃
LTS -60℃~80℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.1℃ at -60℃~-30℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser Air-cooling /Water-cooling · Expansion tank…
- More
LTS -40℃~80℃
LTS -40℃~80℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.1℃ at -40℃~-10℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser Air-cooling /Water-cooling · Expansion tank…
loading…
已经是到最后一篇内容了!