ZLJ-2.5P&4P
Utilizing the condensation effect on the collector surface
- Cooling TypeAir cooling
- Cooling Power5kW &10kW
- RefrigerantR134A
- Suction Pressure300kpa
- Temperature distinguish±0.1℃
Configuration Details
Model | ZLJ-2.5P-S | ZLJ-4P-S |
Cooling Capacity | 5kw~6kw | 10kw |
Refrigerant | R134a | R134a |
Suction pressure (control according to actual battery pack matching) | 300kpa | 300kpa |
Suction pressure control accuracy | ±30kpa | ±30kpa |
Condensing pressure | 1500kpa | 1500kpa |
Condensing pressure control accuracy | ±60kpa | ±60kpa |
Pressure Measurement Resolution | 0.1kpa | 0.1kpa |
Temperature measurement resolution | 0.1℃ | 0.1℃ |
Subcooling degree (expansion valve front end temperature) | 3℃~5℃ | 3℃~5℃ |
Superheat (battery pack outlet temperature) | 0℃~5℃ | 0℃~5℃ |
Cooling method | Air Cooling | Air Cooling |
Compressor | Automotive Air Conditioning Compressor | Automotive Air Conditioning Compressor |
Control screen display | The control pressure, superheat (battery pack outlet temperature), subcooling (expansion valve front temperature), equipment inlet and outlet exhaust pressure and suction pressure, exhaust temperature and suction temperature must be displayed. The above data are displayed in real time and support curves View historical data and export | |
Control System | PLC | PLC |
Protocol | CAN | CAN |
Noise | ≤75dB(A) | ≤75dB(A) |
Total Power | ≤3KW | ≤6KW |
Power Supply | 380V/50HZ | 380V/50HZ |
Size | 550*680*1450(mm) | 1000*1500*1850(mm) |
Product Description
The refrigerant in the refrigeration system is directly output and evaporated into the target control element (heat exchanger) for heat exchange, thereby cooling the target control object. Compared with the fluid (gas) transported into the heat exchanger, it has a higher heat exchange capacity, which is especially suitable for applications where the heat exchange area of the heat exchanger is small but the heat exchange capacity is large. It can also be used as gas capture, the refrigerant is directly passed into the trap to evaporate, and the gas in the space is quickly captured through the condensation effect on the surface of the trap.
Recommended ProductsUsed for Water Test
- More
LTS -80℃~80℃
LTS -80℃~80℃ Fluorinated liquid temperature control system AFor chip testing · Temperature Control Accuracy ±0.1℃ at -80℃~-50℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser A…
- More
LTS -60℃~80℃
LTS -60℃~80℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.1℃ at -60℃~-30℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser Air-cooling /Water-cooling · Expansion tank…
- More
LTS -40℃~80℃
LTS -40℃~80℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.1℃ at -40℃~-10℃ · Flow Control 12~45L/min · Internal Circulating Fluid Volume 4L~10L · Condenser Air-cooling /Water-cooling · Expansion tank…