HRT -45℃~+250℃
PRODUCT ADVANTAGES
· Temperature Control Accuracy ±0.5℃
· Heating Power 2.5kW~15kW
· Cooling Capacity 0.25kW~15kW
· Circulation Pump(Water-cooled) 20L/min~110L/H 2bar
· Refrigerant R404A/R507C
· Types Air Cooling
· Weight 160KG~360KG
Appearance Structure
Product Features
- Temperature range: -45℃~250℃, with heating and cooling function;
- Can achieve continuous temperature control from 250°C to -45°C;
- The circulation pipeline is completely sealed, without oil mist and water absorption, which ensures the safety of the experiment and the life of the heat transfer fluid;
- Refrigeration unit Emerson Copeland compressor, stable performance and reliable quality;
- With self-diagnosis function, freezer overload protection, high pressure pressure switch, overload relay, thermal protection device and other safety functions;
- With an expansion vessel, the expansion vessel and the liquid circulation are adiabatic and do not participate in the liquid circulation, but are only mechanically connected, regardless of whether the temperature of the liquid circulation is high or low The medium in the expansion vessel is below 60°C.
Main Parameters
Model | HRT-25N | HRT-35N | HRT-50N | HRT-70N | HRT-100N | HRT-150N | |
Temperature Range | -45℃~250℃ | ||||||
Controller | PID adaptive controller | ||||||
Temperature Control | heat-conducting medium outlet temp.control | ||||||
Temperature Feedback | Heat-conducting medium temperature feedback PT100(measure inlet temperature and outlet temperature) | ||||||
Temp. Accuracy | ±0.5℃ | ||||||
Heating Power | 2.5KW | 3.5KW | 5.5KW | 7.5KW | 10KW | 15KW | |
Cooling Capacity | 250℃ | 2KW | 3.5KW | 5.5KW | 7.5KW | 10KW | 15KW |
100℃ | 2KW | 3.5KW | 5KW | 7KW | 10KW | 15KW | |
20℃ | 2KW | 3.5KW | 5KW | 7KW | 10KW | 15KW | |
0℃ | 1.8KW | 3KW | 5KW | 7KW | 10KW | 15KW | |
-20℃ | 0.85KW | 1.5KW | 2.8KW | 4.2KW | 6KW | 11KW | |
-40℃ | 0.25KW | 0.45KW | 0.9W | 1.5KW | 2KW | 3.75KW | |
Circulation Pump Flow | Max20L/min | Max35L/min | Max35L/min | Max50L/min | Max65L/min | Max110L/min | |
Circulation Pump Pressure | 1.2BAR | 1.2BAR | 1.2BAR | 1.2BAR | 1.5BAR | 1.5BAR | |
Compressor | Tecumseh | Emerson copeland | |||||
Evaporator | Plate heat exchanger | ||||||
Operation Panel | Display setting temperature and outlet and inlet temperature, 7-inch color touch screen | ||||||
Data Record | U disk data export, Excel form, error record | ||||||
Temperature Record | Record setting temperature, outlet and inlet temperature | ||||||
Safety Protection | Self-diagnosis function; freezer overload protection; high pressure switch; overload relay; thermal protection device and other safety protection. | ||||||
Closed Circulation System | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||||
Refrigerant | R-404A/R507C | ||||||
Connection Size | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | G1 | |
Dimension(cm) | 40*70*130 | 45*70*160 | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | |
Weight | 160kg | 185kg | 245kg | 245kg | 320kg | 360kg | |
Power | AC 220V 50HZ | AC 380V | AC 380V | AC 380V | AC 380V | AC 380V | |
4.5kW | 6.2kW | 9kW | 11.5kW | 16kW | 23kW | ||
Case Material | Cold-rolled sheet spraying (standard color 7035) | ||||||
Optional | MODBUS RTU Protocl, RS 232 interface | ||||||
Optional Power | 220V 60HZ three-phase,440V~480V 60HZ three phase |
Accessories Details
Product Applications
Recommended Products
- More
KRY 0℃~+100℃
KRY 0℃~+100℃ (Normal Temperature) Vehicle Test Chillers · Temperature Control Accuracy ±0.5℃ · Service Acceptance Customization · Heating Power 2.5kW~60kW · Cooling Capacity 1.8kW~60kW · Power 4.5kW~82kW · Re…