WTD -25℃~+300℃
PRODUCT ADVANTAGES
· Temperature Control Accuracy ±0.3℃
· Heating Power 2kW~7.5kW
· Cooling Capacity 1kW~7.5kW
· Circulation Pump(Water-cooled) 7.5L/min 2.5bar~25L/min 3bar
· Refrigerant R404A/R23
· Types Air Cooling
· Weight 195KG~205KG
Appearance Structure
Refrigeration, heating and temperature control system (for microchannel/tubular reactor)
It is specially designed and developed for the characteristics of small liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system of the microchannel reactor.
- Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
- Enhance the design of the circulating pump capacity to meet the high pressure drop requirements of the reactor.
- Continuous high temperature cooling technology to meet the requirement of stable operation when the temperature control is required for high temperature exothermic reaction.
Model | WTD-120M | WTD-255 | WTD-455 | WTD-755 | WTD-275V | |
Temperature range | -5°C~120°C | -25°C~200°C | -45°C~250°C | -70°C~200°C | -20°C~300°C | |
Temperature control accuracy | ±0.3℃ | |||||
Temperature resolution | 0.1K | |||||
Operation panel | 7 inch color touch screen | |||||
Data curve | Data curve record | |||||
Data output | U disk excel format | |||||
Control mode | Fuzzy PID Adaptive Controller | |||||
Communication | RS485 Modbus RTU Protocol | |||||
Heating power | 2KW | 5.5KW | 5.5KW | 5.5KW | 7.5KW | |
Refrigeration ability | 300°C | 7.5KW | ||||
200°C | 5.5kw | 5.5kw | 5.5kw | 7.5kw | ||
100°C | 1.5KW | 5.5kw | 5.5kw | 5.5kw | 7.5kw | |
20°C | 1 KW | 5.5kw | 5.5kw | 5.5kw | 5.5kw | |
-20°C | 2.5kw | 4.5kw | 4.5kw | 2.5kw | ||
-35°C | 2.0kw | 3 kw | ||||
-60°C | 1.1kw | |||||
Circulating pump max | 7L/min 2.5bar | 25L/min 3bar | 25L/min 3ar | 25L/min 3ar | 25L/min 3ar | |
Connection size | R1/2 | R3/4 | R3/4 | R3/4 | R3/4 | |
Temperature Sensor | PT100 | PT100 | PT100 | PT100 | PT100 | |
Compressor | Skop | Emerson Copeland | Emerson Copeland | Tecumseh | Emerson Copeland | |
Evaporator | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger | |
Cooling method | Air cooling | Air cooling + water cooling | Air cooling + water cooling | Air cooling + water cooling | Air cooling + water cooling | |
Expansion valve | Thermal Expansion Valve | Electronic expansion valve | Electronic expansion valve | Electronic expansion valve | Electronic expansion valve | |
Filter drier | Danfoss | Danfoss | Danfoss | Danfoss | Danfoss | |
Refrigerant | 5L | 20L | 20L | 20L | 20L | |
Refrigerant | R404A | R404A | R404A | R404A R23 | R404A | |
Pipe material | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | |
Ultra-high temperature cooling technology | Yes | Yes | Yes | Yes | Yes | |
Metal insulation hose | 1m*2 root | 1.8M*2 root | 1.8M*2 root | 1.8M*2 root | 1.8M*2 root | |
Contactor\Circuit Breaker | Schneider | Schneider | Schneider | Schneider | Schneider | |
Size cm | 35*56*75 | 55*70*175 | 55*70*175 | 65*85*185 | 55*70*175 | |
Weight | 60KG | 195KG | 205KG | 325KG | 245KG | |
shell material | Plastic spraying of cold-rolled sheet (standard color 7035) |
Product Applications
Widely used in the research of production users such as petroleum, chemical industry, materials, pesticides, flavors and fragrances, medicine and various scientific research and experimental projects. It is used to complete the process of crystallization, hydrogenation, polymerization, condensation, heating and mixing, and constant temperature reaction.
Recommended ProductsUsed for Reaction
- More
KRY 0℃~+100℃
KRY 0℃~+100℃ (Normal Temperature) Vehicle Test Chillers · Temperature Control Accuracy ±0.5℃ · Service Acceptance Customization · Heating Power 2.5kW~60kW · Cooling Capacity 1.8kW~60kW · Power 4.5kW~82kW · Re…
- More
KRY -25℃~+100℃
KRY -25℃~+100℃ Chiller For Vehicle Antifreeze · Media Temperature Control Accuracy ±0.5℃ · Extend to -40℃~+135℃ · Heating Power 5.5kW~38kW · Cooling Capacity 2.8kW~38kW · Power 11kW~45kW · Refrigerant R404A/…
- More
KRY -40℃~+100℃
KRY -40℃~+100℃(Low Temperature) Vehicle Test Chillers · Media Temperature Control Accuracy ±0.5℃ · Extend to -40℃~+135℃ · Heating Power 15kW~60kW · Cooling Capacity 3kW~60kW · Power 28kW~102kW · Refrigerant …
- More
TES -60℃~+200℃
TES -60℃~+200℃ Temperature Control System For fuel oil test · Media Temperature Control Accuracy ±0.5℃ · Fuel Oil Temperature Accuracy ±2℃ · Heating Power 15kW~60kW · Cooling Capacity 3kW~60kW · Power 28kW~102k…
- More
TES -85℃~+200℃
TES -85℃~+200℃ PRODUCT ADVANTAGES · Media Temperature Control Accuracy ±0.3℃ · Heating Power 2.5kW~25kW · Cooling Capacity 0.25kW~25kW · Power 6.5kW~50kW · Refrigerant R404A/R508B · Type Water-cooling …
- More
TES -45℃~+250℃
TES -45℃~+250℃ Aging Test Temperature Control · Media Temperature Control Accuracy ±0.3℃ · Heating Power 3kW~25kW · Cooling Capacity 0.3kW~25kW · Power 6kW~36kW · Refrigerant R404A/R507C · Types Air-cooling/Wate…
loading…
已经是到最后一篇内容了!