ZLJ -80℃~-45℃
PRODUCT ADVANTAGES
· Temperature Control Accuracy ±0.5℃
· Compressor 1.5P*2~8P*2
· Power 400V 50Hz 440V 60Hz
· Refrigerant R404A /R507C/R448
Several ZLJ devices can be concentrated in a larger cabinet to achieve multi-channel control requirements.
Appearance Structure
Main Parameters
ZLJ-81 | ZLJ-81.5 | ZLJ-82 | ZLJ-83 | ZLJ-84 | ZLJ-86 | ZLJ-88 | |
ZLJ-81W | ZLJ-81.5W | ZLJ-82W | ZLJ-83W | ZLJ-84W | ZLJ-86W | ZLJ-88W | |
Temperature range | -80℃~-45℃ | ||||||
Temperature control accuracy | ±0.5℃ control evaporation temperature | ||||||
Throttling method | Electronic expansion valve | ||||||
Controller | PLC | ||||||
Show record | 7-inch touch screen, record temperature, system pressure and other information | ||||||
Main components | Danfoss filter drier, Castor solenoid valve, Johnson Controls pressure sensor, EBM fan (air-cooled), Danfoss/Emerson oil separator, | ||||||
Compressor | Secop, Taikang, Emerson, Carlisle | ||||||
Refrigerant | R404A Optional R507C R448 | ||||||
High temperature cooling | With 150 degrees high temperature direct cooling technology, to meet the goal of rapid cooling ability during high temperature operation | ||||||
Compressor | 7/8HP*2 | 1.5HP*2 | 2HP*2 | 3HP*2 | 4HP*2 | 6HP*2 | 8HP*2 |
Power supply V | 220V 50HZ | 380V 50HZ |
Product Application Principle
The refrigerant in the refrigeration system is directly output and evaporated into the target control element (heat exchanger) for heat exchange, thereby cooling the target control object. The heat exchange capacity is generally more than 5 times higher than that of the fluid (gas) transported into the heat exchanger, which is especially suitable for applications where the heat exchange area of the heat exchanger is small but the heat exchange is large. It can also be used such as gas capture, the refrigerant is directly passed into the trap to evaporate, and through the condensation effect on the surface of the trap, it is quickly inferior to the gas in the air.
Product Applications
Recommended Products
- More
ZLJ -120℃~-90℃
ZLJ -120℃~-90℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.5℃ · Compressor 3P*3~45P*3 · Power 400V 50Hz 440V 60Hz · Refrigerant R404A /R23/R14 Request A Quote More Applications …
- More
ZLJ -40℃~-10℃
ZLJ -40℃~-15℃ PRODUCT ADVANTAGES · Temperature Control Accuracy ±0.5℃ · Compressor 1.5P~8P · Power 220V 50Hz · Refrigerant R404A /R507C/R448 Request A Quote More Applications …
- More
SLJ -110℃~-150℃
SLJ -110℃~-150℃ PRODUCT ADVANTAGES · Circulation Pump max 6.6m³/h 2.5br ~50m³/h 2.5bar · Cooling Capacity 1.4kW~11kW · Power 8.6kW~36kW · Weight 320KG~950KG · Refrigerant R404A /R23/R14/R50 Reques…
loading…
已经是到最后一篇内容了!