What is the maintenance and inspection of a 200 ton chiller?
What is the maintenance and inspection of a 200 ton chiller?
1. Check the stability of voltage and current
2. Regularly inspect the compressor
The necessary acceptance tests for the chiller should be carried out in accordance with the principle of first air tightness test, then vacuum test, first sub item test, and then overall test
3. Regular cleaning
In addition to checking the technical performance of the chiller, pay attention to protecting the clean appearance of the cooler and the cleanliness of the work site. When the air-cooled chiller operates for 6 months, the entire system, such as pipelines, filters, condensers, fans, etc., should be cleaned, especially the fans. Like our commonly used fans, they are covered in dust, which affects heat dissipation, thus directly reducing cooling efficiency.
4. Regularly inspect instruments
The temperature controller is out of control, replace the temperature controller, high voltage fault, poor heat dissipation, the radiator is too dirty, the air cannot be cleaned well, improve the ventilation condition, the Computer fan does not work, check whether the fan motor is burned out, repair or replace the motor, the high voltage engine is damaged, and replace the high voltage engine.
Daily maintenance:
① Clean the surface of the unit.
③ Check whether the three-phase voltage of the power supply is normal at 380v.
④ Check whether the oil heater works normally when it is powered on (the oil temperature shall be kept at 25~30 ℃ during standby).
⑤ Check for water and oil leakage in all parts of the body.
⑥ Check whether the temperature control probe is normal.
⑦ Check whether all parameters during the operation of the unit are within the standard values (see the host manual for specific parameters).
⑧ Check whether the energy regulating mechanism operates flexibly during the operation of the unit (i.e. loading and unloading solenoid valves, slide valve mechanisms).
⑨ Check whether the sound of the unit is normal during normal operation.
⑩ Check whether the temperature of the unit during normal operation is normal (including main motor, compressor, exhaust temperature, oil temperature, etc.).
Related recommendations
temperature process control system
44Temperature Process Control Systems: Ensuring Precision in Industrial Processes Temperature process control systems are essential in maintaining the precise temperature conditions required for ...
View detailsefficient chillers
0The Importance of Efficient Chiller Operation Efficient chiller operation is critical in the context of increasing energy costs and environmental concerns. Chillers are responsible for a signif...
View detailsWhat is the method of adding refrigerant to air cooled water chiller system?
490What is the method of adding refrigerant to air cooled water chiller system? Addition of refrigerant During the use of air-cooled chillers, there may be insufficient or missing r...
View detailsWhat is the maintenance method for non circulating cold water in chiller for laboratory?
533What is the maintenance method for non circulating cold water in chiller for laboratory? The water level in the water tank is lower than the water inlet of the water pump Solutio...
View details
HelloPlease log in