What is the maintenance and inspection of a 200 ton chiller?
What is the maintenance and inspection of a 200 ton chiller?
1. Check the stability of voltage and current
2. Regularly inspect the compressor
The necessary acceptance tests for the chiller should be carried out in accordance with the principle of first air tightness test, then vacuum test, first sub item test, and then overall test
3. Regular cleaning
In addition to checking the technical performance of the chiller, pay attention to protecting the clean appearance of the cooler and the cleanliness of the work site. When the air-cooled chiller operates for 6 months, the entire system, such as pipelines, filters, condensers, fans, etc., should be cleaned, especially the fans. Like our commonly used fans, they are covered in dust, which affects heat dissipation, thus directly reducing cooling efficiency.
4. Regularly inspect instruments
The temperature controller is out of control, replace the temperature controller, high voltage fault, poor heat dissipation, the radiator is too dirty, the air cannot be cleaned well, improve the ventilation condition, the Computer fan does not work, check whether the fan motor is burned out, repair or replace the motor, the high voltage engine is damaged, and replace the high voltage engine.
Daily maintenance:
① Clean the surface of the unit.
③ Check whether the three-phase voltage of the power supply is normal at 380v.
④ Check whether the oil heater works normally when it is powered on (the oil temperature shall be kept at 25~30 ℃ during standby).
⑤ Check for water and oil leakage in all parts of the body.
⑥ Check whether the temperature control probe is normal.
⑦ Check whether all parameters during the operation of the unit are within the standard values (see the host manual for specific parameters).
⑧ Check whether the energy regulating mechanism operates flexibly during the operation of the unit (i.e. loading and unloading solenoid valves, slide valve mechanisms).
⑨ Check whether the sound of the unit is normal during normal operation.
⑩ Check whether the temperature of the unit during normal operation is normal (including main motor, compressor, exhaust temperature, oil temperature, etc.).
Related recommendations
closed loop chilled water cooling system
183Closed-Loop Chilled Water Cooling Systems: A Comprehensive Guide Closed-loop chilled water cooling systems are an essential technology for controlling and maintaining temperatures in a variety ...
View detailsclosed loop water chiller system
23A Comprehensive Guide to Closed Loop Water Chiller SystemsClosed loop water chiller systems are widely used in numerous industrial and commercial applications for efficient heat removal and temper...
View detailschiller water plant
180Chiller Water Plants: A Comprehensive Overview Chiller water plants are critical for maintaining comfortable temperatures in commercial buildings, industrial facilities, and data centers. They ...
View details5 tr water chiller
245 TR Water Chiller: A Comprehensive GuideWhat is a 5 TR Water Chiller?A 5 TR water chiller is a cooling device with a cooling capacity of 5 tons of refrigeration. One ton of refrigeration is equiv...
View details
HelloPlease log in