What is the reason why the cryogenic chiller does not cool?

Industry News 7090

  What is the reason why the cryogenic chiller does not cool?

  During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and begins to evaporate. After being compressed by the compressor and throttled by the expansion valve, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator for further circulation.

  If used for too long, the refrigerant will evaporate, which will affect the cooling effect. Another reason is that the refrigerant has leaked, which does not affect refrigeration enough. Therefore, it is important to observe whether the refrigerant is sufficient. In the case of refrigerant leakage, it is necessary to check and repair the leakage. Therefore, it is necessary to regularly check and clean the filter. When the blockage is severe, it is recommended to replace it with a new dry filter.

  Another issue is that there are too many impurities in tap water that adhere to the inner wall of the water pipe, resulting in insufficient water supply and affecting the cooling effect. Therefore, for areas with poor water quality, it is recommended to carry out water treatment projects or regularly clean and replace water pipes to ensure the normal operation of the cold water system.

  The condenser has not been cleaned for a long time and is one of the main components of the chiller. Most cooling water contains calcium, magnesium ions, and acidic carbonates. When the cooling water flows through the metal surface, carbonate is generated. In addition, oxygen dissolved in cooling water can also cause metal corrosion and form rust. Due to the generation of rust and scale, the heat exchange efficiency of the condenser decreases. When the scale is severe, it can block the pipes, making the heat exchange effect ineffective and affecting the refrigeration effect. Therefore, it is recommended to clean the condenser every six months.

  After a period of use, the ice water unit is prone to adsorbing dust and debris. If not cleaned for a long time, it will affect the heat dissipation performance of the machine. Pipelines are also prone to scaling, breeding bacteria, and reducing cooling effectiveness. Therefore, it is necessary to regularly clean and maintain equipment and pipelines.

  Insufficient power supply voltage and excessively long copper pipes between indoor and outdoor units can also cause the chiller or air conditioner to not cool. In addition, if the actual water temperature has already met the requirements, but the temperature on the display screen has not decreased, it is likely that the temperature sensor of the chiller is damaged. In this case, you only need to replace the temperature sensor.

The prev: The next:

Related recommendations

  • thermal chuck

    178

    Thermal chucks are essential in the semiconductor industry for their ability to provide precise temperature control during the testing and processing of semiconductor wafers. These systems are use...

    View details
  • 4 ton air cooled chiller

    214

    4 Ton Air-Cooled Chiller: Specifications and Applications In industrial and commercial settings, the demand for reliable and efficient cooling systems is paramount. A 4-ton air-cooled chiller i...

    View details
  • low temperature cooling system

    243

    Low Temperature Cooling Systems: Achieving Ultra-Low Temperatures for Specialized Applications Low temperature cooling systems are critical in various fields where maintaining ultra-low tempera...

    View details
  • industrial water chiller malaysia

    76

    Industrial Water Chillers in Malaysia: An In - Depth ExplorationIndustrial water chillers are essential cooling equipment in Malaysia's industrial landscape, playing a significant role in maintain...

    View details
Click Cancel to reply
    Expand more!
    1
    Leave a message